Our LED industrial hazardous location lighting fixtures (rated Class I, Division 2) are designed specifically for highly hazardous areas where an explosion may occur due to the constant presents of air borne hazardous materials. Our LED industrial hazardous location lighting fixtures deliver excellent illumination in the most hazardous environments.  A few common applications for a LED industrial hazardous location lighting includes paint booths, petroleum refineries, gasoline storage areas, spray finishing areas and fuel servicing areas.
Our extensive line of LED industrial hazardous location lighting and Explosion proof high lumen lighting includes multiple LED configurations for indoor or outdoor applications. Our LED industrial fixtures are standard non-hazardous, IP65/67 and hazardous location environments.
Class I, Division 2: One of the following three situations must exist in order for an area to be considered a Class I, Division 2 location:
Volatile flammable liquids or flammable gases are handled, processed or used, but the hazardous liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in the event of accidental rupture or breakdown of such containers or systems, or as a result of abnormal operation of equipment.
Ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operations of the ventilating equipment.
Adjacent to a Class I, Division 1 location, and to which ignitable concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive-pressure ventilation from a source of clean air, and effective safeguards against ventilation failure are provided.

Class I, Zone 2: One of the following four situations must exist in order for an area to be considered a Class I, Zone 2 location:
Ignitable concentrations of flammable gases or vapors are not likely to occur in normal operation and if they do occur will exist only for a short period.
Volatile flammable liquids, flammable gases or flammable vapors are handled, processed or used, but in which the liquids, gases or vapors are normally confined within closed containers or closed systems from which they can escape only as a result of accidental rupture or breakdown of the containers or system or as the result of the abnormal operation of the equipment with which the liquids or gases are handled, processed or used.